{{SimTX packet
{{SimTX packet v24
| name = StationList
| name = StationList
| id = 9
| id = 9
| hex = 0x09
| hex = 0x09
| direction = s2c
| direction = s2c
| session = [[SimTX API/Control session|Control]]
| session = [[SimTX API v24/Control session|Control]]
| size = Variable
| size = Variable
| permission = None
| permission = None
| answers = [[SimTX API/Packets/ListStations|ListStations]]
| answers = [[SimTX API v24/Packets/ListStations|ListStations]]
| group = control
| group = control
}}
}}
Line 36: Line 36:
| <code>frequencyHz</code> || <code>f32</code> || Transmitter: carrier frequency. Receiver: centre frequency.
| <code>frequencyHz</code> || <code>f32</code> || Transmitter: carrier frequency. Receiver: centre frequency.
|-
|-
| <code>modulation</code> || <code>UTF</code> || Transmitter: [[SimTX API/Data types#Modulation|Modulation]] name. Receiver: empty.
| <code>modulation</code> || <code>UTF</code> || Transmitter: [[SimTX API v24/Data types#Modulation|Modulation]] name. Receiver: empty.
|-
|-
| <code>powerWatts</code> || <code>f32</code> || Transmitter: requested power. Receiver: 0.
| <code>powerWatts</code> || <code>f32</code> || Transmitter: requested power. Receiver: 0.
Line 50: Line 50:


== Usage ==
== Usage ==
* The list is a snapshot. Poll [[SimTX API/Packets/ListStations|ListStations]] to follow changes, every few seconds at most.
* The list is a snapshot. Poll [[SimTX API v24/Packets/ListStations|ListStations]] to follow changes, every few seconds at most.
* A single server sorts the list by callsign. Through the public gateway, the lists of all server nodes are merged into one, so do not rely on the order.
* A single server sorts the list by callsign. Through the public gateway, the lists of all server nodes are merged into one, so do not rely on the order.
* A station's UUID changes every time it reconnects. Callsigns are not unique.
* A station's UUID changes every time it reconnects. Callsigns are not unique.
* Positions are as the operator entered them.
* Positions are as the operator entered them.


{{SimTX API navbox}}
{{SimTX API v24 navbox}}
[[Category:SimTX API]]
[[Category:SimTX API v24]]

Latest revision as of 16:17, 24 October 2026

This page documents protocol v24, which current servers no longer accept. See SimTX API for v25.
StationList
Packet ID 9(0x09)
Direction Server → client
Session Control
Body size Variable
Permission None
Answered by
Answers ListStations

StationList lists every station currently connected to the server, both transmitters and receivers, with their frequency, mode, power and position.

Layout[edit | edit source]

Field Type Description
packetId u8 Always 9.
count i32 Number of stations, at most 100,000.
stations count × Station See below.

Station[edit | edit source]

Field Type Description
stationUuid UTF Station UUID, unique for the session.
callsign UTF Callsign.
transmitting bool True for a transmitter, false for a receiver.
frequencyHz f32 Transmitter: carrier frequency. Receiver: centre frequency.
modulation UTF Transmitter: Modulation name. Receiver: empty.
powerWatts f32 Transmitter: requested power. Receiver: 0.
latitudeDeg f64 Station latitude.
longitudeDeg f64 Station longitude.
address UTF Client address. Always empty on a control session; filled in only for moderators.
declaredBandwidthHz f32 Transmitter: occupied bandwidth as measured by the server. Receiver: filter bandwidth.

Usage[edit | edit source]

  • The list is a snapshot. Poll ListStations to follow changes, every few seconds at most.
  • A single server sorts the list by callsign. Through the public gateway, the lists of all server nodes are merged into one, so do not rely on the order.
  • A station's UUID changes every time it reconnects. Callsigns are not unique.
  • Positions are as the operator entered them.
SimTX API v24 reference (protocol v24, archived)
Start OverviewQuick startData typesLimits and errorsPacket list
Account service OverviewDevice loginServer directoryGame ticketsPermissionsPublic endpoints
Game protocol Connection and handshakeReceiver sessionTransmitter sessionControl sessionCatalogModeration
Handshake HandshakeHandshakeResult
Receiver ReceiverSessionRequestReceiverRetuneForwardedClientAddressIqStreamDescriptorIqBlockTimedIqBlock
Transmitter TransmitterSessionRequestSampleBlockTxModeInfoTxUpdateTxQueueTxAcceptTxRejectTxKickTxTelemetryTxUpdateAck
Control ControlAckBannerListStationsStationListServerHealthRequestServerHealthReportCoverageMapRequestCoverageMapResponseWeatherMapRequestWeatherMapResponseStartMonitorStopMonitorMonitorBlockMonitorEnd
Catalog CatalogListRequestCatalogListCatalogFetchCatalogEntryCatalogUploadCatalogUploadResultCatalogDeleteCatalogDeleteResult
Moderation KickRequestKickResultIpModerationRequestIpModerationResultBroadcastBannerModerationErrorStationImpactList