SimTX API v24/Packets/MonitorEnd: Difference between revisions
Appearance
m Clanker moved page SimTX API/Packets/MonitorEnd to SimTX API v24/Packets/MonitorEnd: Archive the v24 protocol reference |
Archive the v24 protocol reference: use the v24 templates, links and categories |
||
| Line 1: | Line 1: | ||
{{SimTX API navigation}} | {{SimTX API v24 navigation}} | ||
{{SimTX packet | {{SimTX packet v24 | ||
| name = MonitorEnd | | name = MonitorEnd | ||
| id = 11 | | id = 11 | ||
| hex = 0x0B | | hex = 0x0B | ||
| direction = s2c | | direction = s2c | ||
| session = [[SimTX API/Control session|Control]] | | session = [[SimTX API v24/Control session|Control]] | ||
| size = Variable | | size = Variable | ||
| permission = None | | permission = None | ||
| answers = [[SimTX API/Packets/StartMonitor|StartMonitor]] | | answers = [[SimTX API v24/Packets/StartMonitor|StartMonitor]] | ||
| group = control | | group = control | ||
}} | }} | ||
| Line 37: | Line 37: | ||
|} | |} | ||
{{SimTX API navbox}} | {{SimTX API v24 navbox}} | ||
[[Category:SimTX API]] | [[Category:SimTX API v24]] | ||
Latest revision as of 16:16, 24 October 2026
| Packet ID | 11(0x0B)
|
|---|---|
| Direction | Server → client |
| Session | Control |
| Body size | Variable |
| Permission | None |
| Answers | StartMonitor |
MonitorEnd tells the client that a monitor stream has ended, or could not be started.
Layout[edit | edit source]
| Field | Type | Description |
|---|---|---|
packetId |
u8 |
Always 11.
|
stationUuid |
UTF |
The transmitter. |
reason |
UTF |
Human-readable reason. |
Reasons[edit | edit source]
| Reason | Meaning |
|---|---|
| No live transmitter with that id | No transmitter with that UUID is on air. |
| That transmitter belongs to another client | The transmitter belongs to another account, or the control session is anonymous. |
| Transmitter went off the air | The monitored session ended. |
| Shard connection ended | Through the public gateway: the server node hosting the transmitter became unreachable. |