SimTX API v24/Packets/StopMonitor: Difference between revisions
Appearance
m Clanker moved page SimTX API/Packets/StopMonitor to SimTX API v24/Packets/StopMonitor: Archive the v24 protocol reference |
Archive the v24 protocol reference: use the v24 templates, links and categories |
||
| Line 1: | Line 1: | ||
{{SimTX API navigation}} | {{SimTX API v24 navigation}} | ||
{{SimTX packet | {{SimTX packet v24 | ||
| name = StopMonitor | | name = StopMonitor | ||
| id = 7 | | id = 7 | ||
| hex = 0x07 | | hex = 0x07 | ||
| direction = c2s | | direction = c2s | ||
| session = [[SimTX API/Control session|Control]] | | session = [[SimTX API v24/Control session|Control]] | ||
| size = 2 + UUID length (38 bytes) | | size = 2 + UUID length (38 bytes) | ||
| permission = None | | permission = None | ||
| group = control | | group = control | ||
}} | }} | ||
'''StopMonitor''' ends a monitor stream started with [[SimTX API/Packets/StartMonitor|StartMonitor]]. No [[SimTX API/Packets/MonitorEnd|MonitorEnd]] is sent in reply. A few [[SimTX API/Packets/MonitorBlock|MonitorBlock]] packets already on their way may still arrive. | '''StopMonitor''' ends a monitor stream started with [[SimTX API v24/Packets/StartMonitor|StartMonitor]]. No [[SimTX API v24/Packets/MonitorEnd|MonitorEnd]] is sent in reply. A few [[SimTX API v24/Packets/MonitorBlock|MonitorBlock]] packets already on their way may still arrive. | ||
== Layout == | == Layout == | ||
| Line 21: | Line 21: | ||
|} | |} | ||
{{SimTX API navbox}} | {{SimTX API v24 navbox}} | ||
[[Category:SimTX API]] | [[Category:SimTX API v24]] | ||
Latest revision as of 16:18, 24 October 2026
| Packet ID | 7(0x07)
|
|---|---|
| Direction | Client → server |
| Session | Control |
| Body size | 2 + UUID length (38 bytes) |
| Permission | None |
StopMonitor ends a monitor stream started with StartMonitor. No MonitorEnd is sent in reply. A few MonitorBlock packets already on their way may still arrive.
Layout[edit | edit source]
| Field | Type | Description |
|---|---|---|
packetId |
u8 |
Always 7.
|
stationUuid |
UTF |
UUID of the monitored transmitter. |